BS EN 10219 Square Hollow Cold Formed Sections

Square Hollow Sections - Cold Formed .. BS EN 10219:1997 - Metric Units

square hollow section

DesignationWidthDepthThicknessExt. Corner RadiiInt. Corner RadiiMassArea of SectionSecond Moment of Area
mmmmmmmmmmkg/mcm**2cm**4
insert!20 x 2.020202421.051.30.69
insert!20 x 2.520202.552.51.251.60.77
insert!25 x 2.025252421.361.71.5
insert!25 x 2.525252.552.51.642.11.7
insert!25 x 3.025253631.892.41.8
insert!30 x 2.030302421.682.12.7
insert!30 x 2.530302.552.52.02.63.2
insert!30 x 3.030303632.43.03.5
insert!40 x 2.040402422.32.96.9
insert!40 x 2.540402.552.52.83.68.2
insert!40 x 3.040403633.34.29.3
insert!40 x 4.040404844.25.411.1
insert!50 x 2.050502422.93.714.1
insert!50 x 2.550502.552.53.64.616.9
insert!50 x 3.050503634.35.419.5
insert!50 x 4.050504845.57.023.7
insert!50 x 5.0505051056.68.427.0
insert!60 x 2.060602423.64.525.1
insert!60 x 2.560602.552.54.45.630.3
insert!60 x 3.060603635.26.635.1
insert!60 x 4.060604846.78.643.6
insert!60 x 5.0606051058.110.450.5
insert!60 x 6.0606061269.512.056.1
insert!60 x 6.360606.315.759.459.612.254.4
insert!70 x 2.570702.552.55.26.649.4
insert!70 x 3.070703636.17.857.5
insert!70 x 3.670703.67.23.67.29.266.5
insert!70 x 4.070704848.010.172.1
insert!70 x 5.0707051059.712.484.6
insert!70 x 6.07070612611.314.495.2
insert!70 x 6.370706.315.759.4511.514.793.8
insert!80 x 3.080803637.19.087.8
insert!80 x 3.680803.67.23.68.410.7102
insert!80 x 4.080804849.211.7111
insert!80 x 5.08080510511.314.4131
insert!80 x 6.08080612613.216.8149
insert!80 x 6.380806.315.759.4513.517.2149
insert!80 x 8.080808201216.420.8168
insert!90 x 3.090803638.010.2127
insert!90 x 3.690903.67.23.69.512.1149
insert!90 x 4.0909048410.513.3162
insert!90 x 5.09090510512.816.4193
insert!90 x 6.09090612615.119.2220
insert!90 x 6.390906.315.759.4515.519.7221
insert!90 x 8.090908201218.924.0255
insert!100 x 3.01001003639.011.4177
insert!100 x 4.010010048411.714.9226
insert!100 x 5.0100100510514.418.4271
insert!100 x 6.0100100612617.021.6311
insert!100 x 6.31001006.315.759.4517.522.2314
insert!100 x 8.01001008201221.427.2366
insert!100 x 10.010010010251525.632.6411
insert!100 x 12.010010012362428.336.1408
insert!100 x 12.510010012.537.52529.137.0410
insert!120 x 3.012012036310.813.8312
insert!120 x 4.012012048414.218.1402
insert!120 x 5.0120120510517.522.4485
insert!120 x 6.0120120612620.726.4562
insert!120 x 6.31201206.315.759.4521.427.3572
insert!120 x 8.01201208201226.433.6677
insert!120 x 10.012012010251531.840.6777
insert!120 x 12.012012012362435.845.7806
insert!120 x 12.512012012.537.52536.947.0817
insert!140 x 4.014014048416.821.3652
insert!140 x 5.0140140510520.726.4791
insert!140 x 6.0140140612624.531.2920
insert!140 x 6.31401406.315.759.4525.432.3941
insert!140 x 8.01401408201231.440.01127
insert!140 x 10.014014010251538.148.61312
insert!140 x 12.014014012362443.455.31398
insert!140 x 12.514014012.537.52544.857.01425
insert!150 x 4.015015048418.022.9808
insert!150 x 5.0150150510522.328.4982
insert!150 x 6.0150150612626.433.61146
insert!150 x 6.31501506.315.759.4527.434.81174
insert!150 x 8.01501508201233.943.21412
insert!150 x 10.015015010251541.352.61653
insert!150 x 12.015015012362447.160.11780
insert!150 x 12.515015012.537.52548.762.01817
insert!150 x 16.015015016483258.774.82009
insert!160 x 4.016016048419.324.5987
insert!160 x 5.0160160510523.830.41202
insert!160 x 6.0160160612628.336.01405
insert!160 x 6.31601606.315.759.4529.337.41442
insert!160 x 8.01601608201236.546.41741
insert!160 x 10.016016010251544.456.62048
insert!160 x 12.016016012362450.964.92224
insert!160 x 12.516016012.537.52552.667.02275
insert!160 x 16.016016016483263.781.22546
insert!180 x 4.018018048421.827.71422
insert!180 x 5.0180180510527.034.41737
insert!180 x 6.0180180612632.140.82037
insert!180 x 6.31801806.315.759.4533.342.42096
insert!180 x 8.01801808201241.552.82546
insert!180 x 10.018018010251550.764.63017
insert!180 x 12.018018012362458.574.53322
insert!180 x 12.518018012.537.52560.577.03406
insert!180 x 16.018018016483273.894.03887
insert!200 x 4.020020048424.330.91968
insert!200 x 5.0200200510530.138.42410
insert!200 x 6.0200200612635.845.62833
insert!200 x 6.32002006.315.759.4537.247.42922
insert!200 x 8.02002008201246.559.23566
insert!200 x 10.020020010251557.072.64251
insert!200 x 12.020020012362466.084.14730
insert!200 x 12.520020012.537.52568.387.04859
insert!200 x 16.020020016483283.81075625
insert!220 x 5.0220220510533.242.43238
insert!220 x 6.0220220612639.650.43813
insert!220 x 6.32202206.315.759.4541.252.43940
insert!220 x 8.02202208201251.565.64828
insert!220 x 10.022022010251563.280.65782
insert!220 x 12.022022012362473.593.76487
insert!220 x 12.522022012.537.52576.297.06674
insert!220 x 16.022022016483293.91207812
insert!250 x 5.0250250510538.048.44805
insert!250 x 6.0250250612645.257.65672
insert!250 x 6.32502506.315.759.4547.160.05873
insert!250 x 8.02502508201259.175.27229
insert!250 x 10.025025010251572.792.68707
insert!250 x 12.025025012362484.81089859
insert!250 x 12.525025012.537.52588.011210161
insert!250 x 16.025025016483210913912047
insert!260 x 6.0260260612647.160.06405
insert!260 x 6.32602606.315.759.4549.162.66635
insert!260 x 8.02602608201261.678.48178
insert!260 x 10.026026010251575.896.69865
insert!260 x 12.026026012362488.611311200
insert!260 x 12.526026012.537.52591.911711548
insert!260 x 16.026026016483211414513739
insert!300 x 6.0300300612654.769.69964
insert!300 x 6.33003006.315.759.4557.072.610342
insert!300 x 8.03003008201271.691.212801
insert!300 x 10.030030010251588.411315519
insert!300 x 12.030030012362410413217767
insert!300 x 12.530030012.537.52510813718348
insert!300 x 16.030030016483213417122076
insert!350 x 8.03503508201284.210720681
insert!350 x 10.035035010251510413325189
insert!350 x 12.035035012362412315629054
insert!350 x 12.535035012.537.52512716230045
insert!350 x 16.035035016483215920336511
insert!400 x 10.040040010251512015338216
insert!400 x 12.040040012362414118044319
insert!400 x 12.540040012.537.52514718745877
insert!400 x 16.040040016483218423556154
custom!
DesignationWidthDepthThicknessExt. Corner RadiiInt. Corner RadiiMassArea of SectionSecond Moment of Area
mmmmmmmmmmkg/mcm**2cm**4

Note that rounded corners are not drawn. It makes moving and positioning of the components easier.

Sponsored Links

Tools - accessed from within SketchUp

NOTE!! The insert! and the Tools features works only from the engineeringtoolbox plug-in inside of SketchUp. Add and edit parametric objects to the SketchUp model!

Edit:
undo - redo

Color:
change color! - of the selected object(s) - may be slow for some more complicated objects (save your model first!)

View:
iso - top - front - right - left - back - bottom

Make Component:
make! a component of the selected object. Note that all objects from the Engineering Toolbox are inserted as individual groups. You should transfer a group to a component sharing the same definition when there is more than one instance of the same object. Tips! Rename the object to its final name before making it a component (in outliner or with right click and entity info).

Rotate Object(s):
degrees around red, green or blue axis! (select object(s) first)

Move or Copy Object(s): - move or copy (multiple) selected objects
move/copy! no. copies red green blue (offset from current position)
Make advanced geometric constructions with multiple selections, multiple copies and the offset.
Tip! - Use "Make Component" to save space and reduce computer load when working with multiple copies.

New! Move an Object to an other Objects Position
move! Select two objects - click "move" and one of the objects moves to the position and angle of the other object. Handy when moving between axis systems.

New! Change Insertion Point
You can change the position and angle of an inserting object by pre-selecting an existing object before Insert! The inserted object will inherit the position of the selected object. Handy when working with non-default axis.

Insert Line: - use this feature to add reference lines
red green blue - Start position
red green blue - End position
insert!

Insert Horizontal Plane: - use this feature to add reference planes
insert! red (size) green (size) blue (vertical position)

Insert Vertical Plane: - use this feature to add reference planes
insert! red (horizontal position) green (size) blue (vertical size)
insert! red (size) green (horizontal position) blue (vertical size)

Insert Box: - add a box
insert! red (width) green (depth) blue (height)

Insert external Component: - add an external component from the internet by adding the component url
insert! name url

12 2 9

Sponsored Links