Square Hollow Structural Sections - HSS

Square Hollow Strucural Sections - Imperial Units

square hollow strucural sections hss

Designation Width Depth Thickness Mass Area of Section Second Moment of Area
in in in lb/ft in**2 in**4
insert! 32x32x5/8 32 32 0.63 259.83 76.4 12300
insert! 32x32x1/2 32 32 0.5 210.72 61.9 10100
insert! 32x32x3/8 32 32 0.38 159.37 46.8 7750
insert! 30x30x5/8 30 30 0.63 242.82 71.4 10100
insert! 30x30x1/2 30 30 0.5 197.11 57.9 8320
insert! 30x30x3/8 30 30 0.38 149.16 43.8 6370
insert! 28x28x5/8 28 28 0.63 225.8 66.4 8140
insert! 28x28x1/2 28 28 0.5 183.5 53.9 6730
insert! 28x28x3/8 28 28 0.38 138.95 40.8 5150
insert! 26x26x5/8 26 26 0.63 208.79 61.4 6460
insert! 26x26x1/2 26 26 0.5 169.89 49.9 5350
insert! 26x26x3/8 26 26 0.38 128.74 37.8 4110
insert! 24x24x5/8 24 24 0.63 191.78 56.4 5030
insert! 24x24x1/2 24 24 0.5 156.28 45.9 4170
insert! 24x24x3/8 24 24 0.38 118.53 34.8 3210
insert! 22x22x5/8 22 22 0.63 174.76 51.4 3820
insert! 22x22x1/2 22 22 0.5 142.67 41.9 3190
insert! 22x22x3/8 22 22 0.38 108.32 31.8 2460
insert! 20x20x5/8 20 20 0.63 157.75 46.4 2830
insert! 20x20x1/2 20 20 0.5 129.06 37.9 2370
insert! 20x20x3/8 20 20 0.38 98.12 28.8 1830
insert! 18x18x5/8 18 18 0.63 140.73 41.4 2020
insert! 18x18x1/2 18 18 0.5 115.45 33.9 1700
insert! 18x18x3/8 18 18 0.38 87.91 25.8 1320
insert! 16x16x5/8 16 16 0.58 127.37 35 1370
insert! 16x16x1/2 16 16 0.47 103.3 28.3 1130
insert! 16x16x3/8 16 16 0.35 78.52 21.5 873
insert! 16x16x5/16 16 16 0.29 65.87 18.1 739
insert! 14x14x5/8 14 14 0.58 110.36 30.3 896
insert! 14x14x1/2 14 14 0.47 89.68 24.6 743
insert! 14x14x3/8 14 14 0.35 68.31 18.7 577
insert! 14x14x5/16 14 14 0.29 57.36 15.7 490
insert! 12x12x5/8 12 12 0.58 93.34 25.7 548
insert! 12x12x1/2 12 12 0.47 76.07 20.9 457
insert! 12x12x3/8 12 12 0.35 58.1 16 357
insert! 12x12x5/16 12 12 0.29 48.86 13.4 304
insert! 12x12x1/4 12 12 0.23 39.43 10.8 248
insert! 10x10x5/8 10 10 0.58 76.33 21 304
insert! 10x10x1/2 10 10 0.47 62.46 17.2 256
insert! 10x10x3/8 10 10 0.35 47.9 13.2 202
insert! 10x10x5/16 10 10 0.29 40.35 11.1 172
insert! 10x10x1/4 10 10 0.23 32.63 8.96 141
insert! 10x10x3/16 10 10 0.17 24.73 6.76 108
insert! 9x9x1/2 9 9 0.47 55.66 15.3 182
insert! 9x9x3/8 9 9 0.35 42.79 11.8 145
insert! 9x9x5/16 9 9 0.29 36.1 9.92 124
insert! 9x9x1/4 9 9 0.23 29.23 8.03 102
insert! 9x9x3/16 9 9 0.17 22.18 6.06 78.2
insert! 8x8x5/8 8 8 0.58 59.32 16.4 146
insert! 8x8x1/2 8 8 0.47 48.85 13.5 125
insert! 8x8x3/8 8 8 0.35 37.69 10.4 99.6
insert! 8x8x5/16 8 8 0.29 31.84 8.76 85.6
insert! 8x8x1/4 8 8 0.23 25.82 7.1 70.7
insert! 8x8x3/16 8 8 0.17 19.63 5.37 54.4
insert! 7x7x5/8 7 7 0.58 50.81 14 93.3
insert! 7x7x1/2 7 7 0.47 42.05 11.6 80.5
insert! 7x7x3/8 7 7 0.35 32.58 8.97 64.9
insert! 7x7x5/16 7 7 0.29 27.59 7.59 56.1
insert! 7x7x1/4 7 7 0.23 22.42 6.17 46.5
insert! 7x7x3/16 7 7 0.17 17.08 4.67 36
insert! 6x6x5/8 6 6 0.58 42.3 11.7 55.1
insert! 6x6x1/2 6 6 0.47 35.24 9.74 48.2
insert! 6x6x3/8 6 6 0.35 27.48 7.58 39.4
insert! 6x6x5/16 6 6 0.29 23.34 6.43 34.3
insert! 6x6x1/4 6 6 0.23 19.02 5.24 28.6
insert! 6x6x3/16 6 6 0.17 14.53 3.98 22.3
insert! 6x6x1/8 6 6 0.12 9.86 2.7 15.5
insert! 5-1/2x5-1/2x3/8 5.5 5.5 0.35 24.93 6.88 29.7
insert! 5-1/2x5-1/2x5/16 5.5 5.5 0.29 21.21 5.85 25.9
insert! 5-1/2x5-1/2x1/4 5.5 5.5 0.23 17.32 4.77 21.7
insert! 5-1/2x5-1/2x3/16 5.5 5.5 0.17 13.25 3.63 17
insert! 5-1/2x5-1/2x1/8 5.5 5.5 0.12 9.01 2.46 11.8
insert! 5x5x1/2 5 5 0.47 28.43 7.88 26
insert! 5x5x3/8 5 5 0.35 22.37 6.18 21.7
insert! 5x5x5/16 5 5 0.29 19.08 5.26 19
insert! 5x5x1/4 5 5 0.23 15.62 4.3 16
insert! 5x5x3/16 5 5 0.17 11.97 3.28 12.6
insert! 5x5x1/8 5 5 0.12 8.16 2.23 8.8
insert! 4-1/2x4-1/2x1/2 4.5 4.5 0.47 25.03 6.95 18
insert! 4-1/2x4-1/2x3/8 4.5 4.5 0.35 19.82 5.48 15.3
insert! 4-1/2x4-1/2x5/16 4.5 4.5 0.29 16.96 4.68 13.5
insert! 4-1/2x4-1/2x1/4 4.5 4.5 0.23 13.91 3.84 11.4
insert! 4-1/2x4-1/2x3/16 4.5 4.5 0.17 10.7 2.93 9.02
insert! 4-1/2x4-1/2x1/8 4.5 4.5 0.12 7.31 2 6.35
insert! 4x4x1/2 4 4 0.47 21.63 6.02 11.9
insert! 4x4x3/8 4 4 0.35 17.27 4.78 10.3
insert! 4x4x5/16 4 4 0.29 14.83 4.1 9.14
insert! 4x4x1/4 4 4 0.23 12.21 3.37 7.8
insert! 4x4x3/16 4 4 0.17 9.42 2.58 6.21
insert! 4x4x1/8 4 4 0.12 6.46 1.77 4.4
insert! 3-1/2x3-1/2x3/8 3.5 3.5 0.35 14.72 4.09 6.48
insert! 3-1/2x3-1/2x5/16 3.5 3.5 0.29 12.7 3.52 5.84
insert! 3-1/2x3-1/2x1/4 3.5 3.5 0.23 10.51 2.91 5.04
insert! 3-1/2x3-1/2x3/16 3.5 3.5 0.17 8.15 2.24 4.05
insert! 3-1/2x3-1/2x1/8 3.5 3.5 0.12 5.61 1.54 2.9
insert! 3x3x3/8 3 3 0.35 12.17 3.39 3.77
insert! 3x3x5/16 3 3 0.29 10.58 2.94 3.45
insert! 3x3x1/4 3 3 0.23 8.81 2.44 3.02
insert! 3x3x3/16 3 3 0.17 6.87 1.89 2.46
insert! 3x3x1/8 3 3 0.12 4.75 1.3 1.78
insert! 2-1/2x2-1/2x5/16 2.5 2.5 0.29 8.45 2.35 1.82
insert! 2-1/2x2-1/2x1/4 2.5 2.5 0.23 7.11 1.97 1.63
insert! 2-1/2x2-1/2x3/16 2.5 2.5 0.17 5.59 1.54 1.35
insert! 2-1/2x2-1/2x1/8 2.5 2.5 0.12 3.9 1.07 1
insert! 2-1/4x2-1/4x1/4 2.25 2.25 0.23 6.26 1.74 1.13
insert! 2-1/4x2-1/4x3/16 2.25 2.25 0.17 4.96 1.37 0.95
insert! 2-1/4x2-1/4x1/8 2.25 2.25 0.12 3.48 0.96 0.71
insert! 2x2x1/4 2 2 0.23 5.41 1.51 0.75
insert! 2x2x3/16 2 2 0.17 4.32 1.19 0.64
insert! 2x2x1/8 2 2 0.12 3.05 0.84 0.49
insert! 1-3/4x1-3/4x3/16 1.75 1.75 0.17 3.68 1.02 0.41
insert! 1-5/8x1-5/8x3/16 1.625 1.625 0.17 3.36 0.93 0.31
insert! 1-5/8x1-5/8x1/8 1.625 1.625 0.12 2.42 0.67 0.25
insert! 1-1/2x1-1/2x3/16 1.5 1.5 0.17 3.04 0.84 0.24
insert! 1-1/2x1-1/2x1/8 1.5 1.5 0.12 2.2 0.61 0.19
insert! 1-1/4x1-1/4x3/16 1.25 1.25 0.17 2.4 0.67 0.12
insert! 1-1/4x1-1/4x1/8 1.25 1.25 0.12 1.78 0.49 0.1
custom!
in in in lb/ft in**2 in**4
Designation Width Depth Thickness Mass Area of Section Second Moment of Area

Note that rounded corners are not drawn. It makes moving and positioning of the components easier.

Sponsored Links

Tools - accessed from within SketchUp

NOTE!! The ""insert!" and the Tools features works only from the engineeringtoolbox plug-in inside of SketchUp. Add and edit parametric objects to the SketchUp model!

Edit:
undo - redo

Color:
change color! - of the selected object(s) - may be slow for some more complicated objects (save your model first!)

View:
iso - top - front - right - left - back - bottom

Make Component:
make! a component of the selected object. Note that all objects from the Engineering Toolbox are inserted as individual groups. You should transfer a group to a component sharing the same definition when there is more than one instance of the same object. Tips! Rename the object to its final name before making it a component (in outliner or with right click and entity info).

Rotate Object(s):
degrees around red, green or blue axis! (select object(s) first)

Move or Copy Object(s): - move or copy (multiple) selected objects
move/copy! no. copies red green blue (offset from current position)
Make advanced geometric constructions with multiple selections, multiple copies and the offset.
Tip! - Use "Make Component" to save space and reduce computer load when working with multiple copies.

Move an Object to another Objects Position
move! Select two objects - click "move" and one of the objects moves to the position and angle of the other object. Handy when moving between axis systems.

Change Insertion Point
You can change the position and angle of an inserting object by pre-selecting an existing object before Insert! The inserted object will inherit the position of the selected object. Handy when working with non-default axis.

Insert Line: - use this feature to add reference lines
red green blue - Start position
red green blue - End position
insert!

Insert Horizontal Plane: - use this feature to add reference planes
insert! red (size) green (size) blue (vertical position)

Insert Vertical Plane: - use this feature to add reference planes
insert! red (horizontal position) green (size) blue (vertical size)
insert! red (size) green (horizontal position) blue (vertical size)

Insert Box: - add a box
insert! red (width) green (depth) blue (height)

Insert external Component: - add an external component from the internet by adding the component url
insert! name url

Sponsored Links