BS EN 10219 Rectangular Hollow Cold Formed Sections

Rectangular Hollow Sections - Cold Formed .. BS EN 10219:1997 - Metric Units

rectangular hollow section

DesignationWidthDepthThicknessExt. Corner RadiiInt. Corner RadiiMassArea of SectionSecond Moment of Area - IxSecond Moment of Area - Iy
mmmmmmmmmmkg/mcm**2cm**4cm**4
insert!40 x 20 x 2.020402421.72.144.051.34
insert!40 x 20 x 2.520402.552.52.02.594.691.54
insert!40 x 20 x 3.020403632.43.015.211.68
insert!50 x 25 x 2.025502422.22.748.382.81
insert!50 x 25 x 2.525502.552.52.63.349.893.28
insert!50 x 25 x 3.025503633.13.9111.23.67
insert!50 x 30 x 2.030502422.32.949.544.29
insert!50 x 30 x 2.530502.552.52.83.5911.35.05
insert!50 x 30 x 3.030503633.34.2112.85.70
insert!50 x 30 x 4.030504844.25.3515.36.69
insert!60 x 40 x 2.040602422.93.7418.49.83
insert!60 x 40 x 2.540602.552.53.64.5922.111.7
insert!60 x 40 x 3.040603634.35.4125.413.4
insert!60 x 40 x 4.040604845.56.9531.016.3
insert!60 x 40 x 5.0406051056.68.3635.318.4
insert!70 x 50 x 2.050702423.64.5431.518.8
insert!70 x 50 x 2.550702.552.54.45.5938.022.6
insert!70 x 50 x 3.050703635.26.6144.126.1
insert!70 x 50 x 4.050704846.78.5554.732.2
insert!70 x 50 x 5.0507051058.110.463.537.2
insert!80 x 40 x 2.040802423.64.5437.412.7
insert!80 x 40 x 2.540802.552.54.45.5945.115.3
insert!80 x 40 x 3.040803635.26.6152.317.6
insert!80 x 40 x 4.040804846.78.5564.821.5
insert!80 x 40 x 5.0408051058.110.475.124.6
insert!80 x 60 x 2.060802424.25.3449.531.9
insert!80 x 60 x 2.560802.552.55.26.5960.138.6
insert!80 x 60 x 3.060803636.17.8170.044.9
insert!80 x 60 x 4.060804848.010.187.956.1
insert!80 x 60 x 5.0608051059.712.410365.7
insert!90 x 50 x 2.050902424.25.3457.923.4
insert!90 x 50 x 2.550902.552.55.26.5970.328.2
insert!90 x 50 x 3.050903636.17.8181.932.7
insert!90 x 50 x 3.650903.67.23.67.29.2394.737.7
insert!90 x 50 x 4.050904848.010.110340.7
insert!90 x 50 x 5.0509051059.712.412147.4
insert!100 x 40 x 2.5401002.552.55.26.5979.318.8
insert!100 x 40 x 3.0401003636.17.8192.321.7
insert!100 x 40 x 4.0401004848.010.111626.7
insert!100 x 40 x 5.0401005.01059.712.413630.8
insert!100 x 50 x 2.5501002.552.55.67.0991.231.1
insert!100 x 50 x 3.0501003636.68.4110636.1
insert!100 x 50 x 4.0501004848.610.913444.9
insert!100 x 50 x 5.050100510510.513.415852.5
insert!100 x 50 x 6.050100612612.315.617958.7
insert!100 x 50 x 6.3501006.315.759.4512.515.917658.2
insert!100 x 60 x 3.0601003637.19.0112154.6
insert!100 x 60 x 3.6601003.67.23.68.410.714063.3
insert!100 x 60 x 4.0601004849.211.715368.7
insert!100 x 60 x 5.060100510511.314.418180.8
insert!100 x 60 x 6.060100612613.216.820591.2
insert!100 x 60 x 6.3601006.315.759.4513.517.220390.9
insert!100 80 x x 2.5801002.552.56.78.5912790.2
insert!100 x 80 x 3.0801003638.010.2149106
insert!100 x 80 x 4.08010048410.513.3189134
insert!100 x 80 x 5.080100510512.816.4226160
insert!100 x 80 x 6.080100612615.119.2258182
insert!100 x 80 x 6.3801006.315.759.4515.519.7259183
insert!120 x 60 x 2.5601202.552.56.88.5916155.2
insert!120 x 60 x 3.0601203638.010.218964.4
insert!120 x 60 x 3.6601203.67.23.69.512.122174.8
insert!120 x 60 x 4.06012048410.513.324181.2
insert!120 x 60 x 5.060120510512.816.428796.0
insert!120 x 60 x 6.060120612615.119.2328109
insert!120 x 60 x 6.3601206.315.759.4515.519.7327109
insert!120 x 60 x 8.0601208201218.924.0375124
insert!120 x 80 x 3.0801203639.011.4230123
insert!120 x 80 x 4.08012048411.714.9295157
insert!120 x 80 x 5.080120510514.418.4353188
insert!120 x 80 x 6.080120612617.021.6406215
insert!120 x 80 x 6.3801206.315.759.4517.522.2408217
insert!120 x 80 x 8.0801208201221.427.2476252
insert!140 x 80 x 4.08014048413.016.5430180
insert!140 x 80 x 5.080140510516.020.4517216
insert!140 x 80 x 6.080140612618.924.0597248
insert!140 x 80 x 6.3801406.315.759.4519.424.8603251
insert!140 x 80 x 8.0801408201223.930.4708293
insert!150 x 100 x 4.010015048414.918.9595319
insert!150 x 100 x 5.0100150510518.323.4719384
insert!150 x 100 x 6.0100150612621.727.6835444
insert!150 x 100 x 6.31001506.315.759.4522.428.5848453
insert!150 x 100 x 8.01001508201227.735.21008536
insert!150 x 100 x 10.010015010251533.442.61162614
insert!150 x 100 x 12.010015012362437.748.11207642
insert!150 x 100 x 12.510015012.537.52538.949.51225651
insert!160 x 80 x 4.08016048414.218.1598204
insert!160 x 80 x 5.080160510517.522.4722244
insert!160 x 80 x 6.080160612620.726.4836281
insert!160 x 80 x 6.3801606.315.759.4521.427.3846286
insert!160 x 80 x 8.0801608201226.433.61001335
insert!160 x 80 x 10.08016010251531.840.61146380
insert!160 x 80 x 12.08016012362435.845.71171391
insert!160 x 80 x 12.58016012.537.52536.947.01185396
insert!180 x 100 x 4.010018048416.821.3926374
insert!180 x 100 x 5.0100180510520.726.41124452
insert!180 x 100 x 6.0100180612624.531.21310524
insert!180 x 100 x 6.31001806.315.759.4525.432.31335536
insert!180 x 100 x 8.01001808201231.440.01598637
insert!180 x 100 x 10.010018010251538.148.61859736
insert!180 x 100 x 12.010018012362443.455.31965782
insert!180 x 100 x 12.510018012.537.52544.8572001796
insert!200 x 100 x 4.010020048418.022.91200411
insert!200 x 100 x 5.0100200510522.328.41459497
insert!200 x 100 x 6.0100200612626.433.61703577
insert!200 x 100 x 6.31002006.315.759.4527.434.81739591
insert!200 x 100 x 8.01002008201233.943.22091705
insert!200 x 100 x 10.010020010251541.352.62444818
insert!200 x 100 x 12.010020012362447.160.12607876
insert!200 x 100 x 12.510020012.537.52548.762.02659892
insert!200 x 120 x 4.012020048419.324.51353618
insert!200 x 120 x 5.0120200510523.830.41649750
insert!200 x 120 x 6.0120200612628.336.01929874
insert!200 x 120 x 6.31202006.315.759.4529.337.41976898
insert!200 x 120 x 8.01202008201236.546.423861079
insert!200 x 120 x 10.012020010251544.456.628061262
insert!200 x 120 x 12.012020012362450.964.930311368
insert!200 x 120 x 12.512020012.537.52552.667.030991397
insert!250 x 100 x 5.0100250510526.233.42554610
insert!250 x 100 x 6.0100250612631.139.62992710
insert!250 x 100 x 6.31002506.315.759.4532.341.13066730
insert!250 x 100 x 8.01002508201240.251.23714875
insert!250 x 100 x 10.010025010251549.162.643841021
insert!250 x 100 x 12.510025012.537.52558.574.548681133
insert!250 x 150 x 5.0150250510530.138.433041508
insert!250 x 150 x 6.0150250612635.845.638861768
insert!250 x 150 x 6.31502506.315.759.4537.247.440011825
insert!250 x 150 x 8.01502508201246.559.248862219
insert!250 x 150 x 10.015025010251557.072.658252634
insert!250 x 150 x 12.015025012362466.084.164582925
insert!250 x 150 x 12.515025012.537.52568.387.066333002
insert!250 x 150 x 16.015025016483283.810776603453
insert!260 x 180 x 5.0180260510533.242.441212350
insert!260 x 180 x 6.31802606.315.759.4541.252.550132856
insert!260 x 180 x 8.01802608201251.565.661453493
insert!260 x 180 x 10.018026010251563.280.673634174
insert!260 x 180 x 12.018026012362473.593.782454679
insert!260 x 180 x 12.518026012.537.52576.297.084824812
insert!260 x 180 x 16.018026016483293.912099235614
insert!300 x 100 x 6.0100300612635.845.64777842
insert!300 x 100 x 6.31003006.315.759.4537.247.44907868
insert!300 x 100 x 8.01003008201246.559.259781045
insert!300 x 100 x 10.010030010251557.072.671061224
insert!300 x 100 x 12.010030012362466.084.178081343
insert!300 x 100 x 12.510030012.537.52568.387.080101374
insert!300 x 100 x 16.010030016483283.810791571543
insert!300 x 150 x 6.0150300612640.551.660742080
insert!300 x 150 x 6.31503006.315.759.4542.253.762662150
insert!300 x 150 x 8.01503008201252.867.276842623
insert!300 x 150 x 10.015030010251564.882.692093125
insert!300 x 150 x 12.015030012362475.496.1102983498
insert!300 x 150 x 12.515030012.537.52578.199.5105943595
insert!300 x 150 x 16.015030016483296.4123123874174
insert!300 x 200 x 6.0200300612645.257.673703962
insert!300 x 200 x 6.32003006.315.759.4547.160.076244104
insert!300 x 200 x 8.02003008201259.175.293895042
insert!300 x 200 x 10.020030010251572.792.6113136058
insert!300 x 200 x 12.020030012362484.8108127886854
insert!300 x 200 x 12.520030012.537.52588.0112131797060
insert!300 x 200 x 16.0200300164832109139156178340
insert!350 x 250 x 6.0250350612654.769.6124577458
insert!350 x 250 x 6.32503506.315.759.455772.6129237744
insert!350 x 250 x 8.02503508201271.691.2160019573
insert!350 x 250 x 10.0 25035010251588.41131940711588
insert!350 x 250 x 12.02503501236241041322219713261
insert!350 x 250 x 12.525035012.537.5251081372292213690
insert!350 x 250 x 16.02503501648321341712758016434
insert!400 x 200 x 8.02004008201271.691.2189746517
insert!400 x 200 x 10.020040010251588.4113230037864
insert!400 x 200 x 12.520040012.537.525108137271009260
insert!400 x 200 x 16.02004001648321341713254711056
insert!400 x 300 x 8.03004008201284.21072512216212
insert!400 x 300 x 10.03004001025151041333060919726
insert!400 x 300 x 12.03004001236241231563528422747
insert!400 x 300 x 12.530040012.537.5251271623648923517
insert!400 x 300 x16.03004001648321592034435028535
custom!
DesignationWidthDepthThicknessExt. Corner RadiiInt. Corner RadiiMassArea of SectionSecond Moment of Area - IxSecond Moment of Area - Iy
mmmmmmmmmmkg/mcm**2cm**4cm**4

Note that rounded corners are not drawn. It makes moving and positioning of the components easier.

Sponsored Links

Tools - accessed from within SketchUp

The insert! and the Tools features works only from the inside of SketchUp. Add and edit parametric objects to the SketchUp model!

Edit:
undo - redo

Color:
change color! - of the selected object(s) - may be slow for some more complicated objects (save your model first!)

View:
iso - top - front - right - left - back - bottom

Make Component:
make! a component of the selected object. Note that all objects from the Engineering Toolbox are inserted as individual groups. You should transfer a group to a component sharing the same definition when there is more than one instance of the same object. Tips! Rename the object to its final name before making it a component (in outliner or with right click and entity info).

Rotate Object(s):
degrees around red, green or blue axis! (select object(s) first)

Move or Copy Object(s): - move or copy (multiple) selected objects
move/copy! no. copies red green blue (offset from current position)
Make advanced geometric constructions with multiple selections, multiple copies and the offset.
Tip! - Use "Make Component" to save space and reduce computer load when working with multiple copies.

New! Move an Object to an other Objects Position
move! Select two objects - click "move" and one of the objects moves to the position and angle of the other object. Handy when moving between axis systems.

New! Change Insertion Point
You can change the position and angle of an inserting object by pre-selecting an existing object before Insert! The inserted object will inherit the position of the selected object. Handy when working with non-default axis.

Insert Line: - use this feature to add reference lines
red green blue - Start position
red green blue - End position
insert!

Insert Horizontal Plane: - use this feature to add reference planes
insert! red (size) green (size) blue (vertical position)

Insert Vertical Plane: - use this feature to add reference planes
insert! red (horizontal position) green (size) blue (vertical size)
insert! red (size) green (horizontal position) blue (vertical size)

Insert Box: - add a box
insert! red (width) green (depth) blue (height)

Insert external Component: - add an external component from the internet by adding the component url
insert! name url

10 3 21

Sponsored Links