UK - Flat Sections

UK flat structural sections

uk flat sections

DesignationWidthDepthWeight
mmmmkg/m
insert!FLAT 10 x 33100.24
insert!FLAT 13 x 33130.32
insert!FLAT 13 x 55130.48
insert!FLAT 13 x 66130.61
insert!FLAT 16 x 33160.38
insert!FLAT 16 x 55160.63
insert!FLAT 16 x 66160.75
insert!FLAT 20 x 33200.47
insert!FLAT 20 x 55200.79
insert!FLAT 20 x 66200.94
insert!FLAT 20 x 88201.25
insert!FLAT 20 x 1010201.57
insert!FLAT 20 x 1212201.88
insert!FLAT 25 x 3 3250.59
insert!FLAT 25 x 55250.98
insert!FLAT 25 x 66251.18
insert!FLAT 25 x 88251.57
insert!FLAT 25 x 1010251.96
insert!FLAT 25 x 1212252.36
insert!FLAT 25 x 1515252.94
insert!FLAT 25 x 2020253.93
insert!FLAT 30 x 33300.71
insert!FLAT 30 x 55301.18
insert!FLAT 30 x 66301.41
insert!FLAT 30 x 88301.88
insert!FLAT 30 x 1010302.36
insert!FLAT 30 x 1212302.83
insert!FLAT 30 x 1515303.53
insert!FLAT 30 x 2020304.71
insert!FLAT 35 x 33350.82
insert!FLAT 35 x 55351.37
insert!FLAT 35 x 66351.65
insert!FLAT 35 x 88352.2
insert!FLAT 35 x 1010352.75
insert!FLAT 35 x 1212353.3
insert!FLAT 35 x 1515354.12
insert!FLAT 35 x 2020355.5
insert!FLAT 35 x 2525356.87
insert!FLAT 40 x 33400.94
insert!FLAT 40 x 55401.57
insert!FLAT 40 x 66401.88
insert!FLAT 40 x 88402.51
insert!FLAT 40 x 1010403.14
insert!FLAT 40 x 1212403.77
insert!FLAT 40 x 1515404.71
insert!FLAT 40 x 2020406.28
insert!FLAT 40 x 2525407.85
insert!FLAT 40 x 3030409.42
insert!FLAT 45 x 33451.06
insert!FLAT 45 x 55451.77
insert!FLAT 45 x 66452.12
insert!FLAT 45 x 88452.83
insert!FLAT 45 x 1010453.53
insert!FLAT 45 x 1212454.24
insert!FLAT 45 x 1515455.3
insert!FLAT 45 x 2020457.07
insert!FLAT 45 x 2525458.83
insert!FLAT 50 x 33501.18
insert!FLAT 50 x 55501.96
insert!FLAT 50 x 66502.36
insert!FLAT 50 x 88503.14
insert!FLAT 50 x 1010503.93
insert!FLAT 50 x 1212504.72
insert!FLAT 50 x 1515505.89
insert!FLAT 50 x 2020507.85
insert!FLAT 50 x 2525509.81
insert!FLAT 50 x 30305011.8
insert!FLAT 50 x 40405015.7
insert!FLAT 60 x 55602.36
insert!FLAT 60 x 66602.83
insert!FLAT 60 x 88603.77
insert! FLAT 60 x 1010604.71
insert!FLAT 60 x 1212605.66
insert!FLAT 60 x 1515607.07
insert!FLAT 60 x 20 20609.42
insert!FLAT 60 x 25256011.8
insert!FLAT 60 x 30306014.13
insert!FLAT 65 x 55652.55
insert!FLAT 65 x 66653.06
insert!FLAT 65 x 88654.08
insert!FLAT 65 x 1010655.1
insert!FLAT 65 x 1212656.12
insert!FLAT 65 x 1515657.65
insert!FLAT 65 x 20206510.2
insert!FLAT 65 x 25256512.8
insert!FLAT 65 x 40406520.4
insert!FLAT 65 x 50506525.5
insert!FLAT 70 x 66703.3
insert!FLAT 70 x 88704.4
insert!FLAT 70 x 1010705.5
insert!FLAT 70 x 1212706.6
insert!FLAT 70 x 1515708.24
insert!FLAT 70 x 20207011
insert!FLAT 70 x 25257013.7
insert!FLAT 70 x 30307016.5
insert!FLAT 70 x 40407022
insert!FLAT 75 x 66753.53
insert!FLAT 75 x 88754.71
insert!FLAT 75 x 1010755.89
insert!FLAT 75 x 1212757.06
insert!FLAT 75 x 1515758.83
insert!FLAT 75 x 20207511.8
insert!FLAT 75 x 25257514.7
insert!FLAT 80 x 33801.88
insert!FLAT 80 x 55803.14
insert!FLAT 80 x 66803.77
insert!FLAT 80 x 88805.02
insert!FLAT 80 x 1010806.28
insert!FLAT 80 x 1212807.54
insert!FLAT 80 x 1515809.42
insert!FLAT 80 x 20208012.6
insert!FLAT 80 x 25258015.7
insert!FLAT 80 x 30308018.8
insert!FLAT 80 x 50508031.4
insert!FLAT 90 x 55903.53
insert!FLAT 90 x 66904.24
insert!FLAT 92 x 88905.65
insert!FLAT 90 x 1010907.07
insert!FLAT 90 x 1212908.48
insert!FLAT 90 x 15159010.6
insert!FLAT 90 x 20209014.1
insert!FLAT 90 x 25259017.7
insert!FLAT 90 x 30309021.2
insert!FLAT 100 x 331002.36
insert!FLAT 100 x 551003.93
insert!FLAT 100 x 661004.71
insert!FLAT 100 x 881006.28
insert!FLAT 100 x 10101007.85
insert!FLAT 100 x 12121009.42
insert!FLAT 100 x 151510011.8
insert!FLAT 100 x 202010015.7
insert!FLAT 100 x 252510019.6
insert!FLAT 100 x 303010023.6
insert!FLAT 100 x 404010031.4
insert!FLAT 100 x 505010039.3
insert!FLAT 110 x 661105.18
insert!FLAT 110 x 881106.91
insert!FLAT 110 x 10101108.64
insert!FLAT 110 x 121211010.4
insert!FLAT 110 x 151511013
insert!FLAT 110 x 202011017.3
insert!FLAT 110 x 252511021.64
insert!FLAT 120 x 661205.65
insert!FLAT 120 x 881207.54
insert!FLAT 120 x 10101209.42
insert!FLAT 120 x 121212011.3
insert!FLAT 120 x 151512014.13
insert!FLAT 120 x 202012018.8
insert!FLAT 120 x 252512023.6
insert!FLAT 130 x 551305.1
insert!FLAT 130 x 661306.12
insert!FLAT 130 x 881308.16
insert!FLAT 130 x 101013010.21
insert!FLAT 130 x 121213012.25
insert!FLAT 130 x 151513015.31
insert!FLAT 130 x 202013020.41
insert!FLAT 130 x 252513025.51
insert!FLAT 130 x 303013030.62
insert!FLAT 140 x 661406.59
insert!FLAT 140 x 121214013.2
insert!FLAT 140 x 151514016.49
insert!FLAT 140 x 252514027.48
insert!FLAT 150 x 551505.89
insert!FLAT 150 x 661507.07
insert!FLAT 150 x 881509.42
insert!FLAT 150 x 101015011.78
insert!FLAT 150 x 121215014.13
insert!FLAT 150 x 151515017.66
insert!FLAT 150 x 202015023.55
insert!FLAT 150 x 252515029.44
insert!FLAT 150 x 303015035.33
insert!FLAT 150 x 404015047.1
insert!FLAT 180 x 661808.48
insert!FLAT 180 x 8818011.3
insert!FLAT 180 x 101018014.13
insert!FLAT 180 x 121218016.96
insert!FLAT 180 x 151518021.2
insert!FLAT 180 x 202018028.26
insert!FLAT 180 x 252518035.33
insert!FLAT 200 x 662009.42
insert!FLAT 200 x 8820012.6
insert!FLAT 200 x 101020015.7
insert!FLAT 200 x 121220018.84
insert!FLAT 200 x 151520023.55
insert!FLAT 200 x 202020031.4
insert!FLAT 200 x 252520039.25
insert!FLAT 220 x 552208.64
insert!FLAT 220 x 6622010.36
insert!FLAT 220 x 8822013.82
insert!FLAT 220 x 101022017.27
insert!FLAT 220 x 121222020.72
insert!FLAT 220 x 151522025.91
insert!FLAT 220 x 202022034.54
insert!FLAT 220 x 252522043.18
insert!FLAT 230 x 101023018.1
insert!FLAT 230 x 151523027.1
insert!FLAT 230 x 202023036.1
insert!FLAT 230 x 252523045.1
insert!FLAT 250 x 6625011.78
insert!FLAT 250 x 8825015.7
insert!FLAT 250 x 101025019.6
insert!FLAT 250 x 121225023.55
insert!FLAT 250 x 151525029.44
insert!FLAT 250 x 202025039.25
insert!FLAT 250 x 252525049.06
insert!FLAT 300 x 6630014.13
insert!FLAT 300 x 8830018.84
insert!FLAT 300 x 101030023.55
insert!FLAT 300 x 121230028.26
insert!FLAT 300 x 151530035.33
insert!FLAT 300 x 202030047.1
insert!FLAT 300 x 252530058.88
insert!FLAT 350 x 101035027.48
insert!FLAT 350 x 121235033
insert!FLAT 350 x 151535041.21
insert!FLAT 350 x 202035054.95
insert!FLAT 350 x 252535068.69
insert!FLAT 400 x 101040031.4
insert!FLAT 400 x 121240037.7
insert!FLAT 400 x 151540047.1
insert!FLAT 400 x 202040062.8
insert!FLAT 400 x 252540078.5
insert!FLAT 450 x 20 2045070.7
insert!FLAT 450 x 252545088.3
insert!FLAT 500 x 202050078.5
insert!FLAT 500 x 252550098.1
insert!FLAT 500 x 3030500118
custom!
DesignationWidthDepthWeight
mmmmkg/m


Sponsored Links

Tools - accessed from within SketchUp

The insert! and the Tools features works only from the inside of SketchUp. Add and edit parametric objects to the SketchUp model!

Edit:
undo - redo

Color:
change color! - of the selected object(s) - may be slow for some more complicated objects (save your model first!)

View:
iso - top - front - right - left - back - bottom

Make Component:
make! a component of the selected object. Note that all objects from the Engineering Toolbox are inserted as individual groups. You should transfer a group to a component sharing the same definition when there is more than one instance of the same object. Tips! Rename the object to its final name before making it a component (in outliner or with right click and entity info).

Rotate Object(s):
degrees around red, green or blue axis! (select object(s) first)

Move or Copy Object(s): - move or copy (multiple) selected objects
move/copy! no. copies red green blue (offset from current position)
Make advanced geometric constructions with multiple selections, multiple copies and the offset.
Tip! - Use "Make Component" to save space and reduce computer load when working with multiple copies.

New! Move an Object to an other Objects Position
move! Select two objects - click "move" and one of the objects moves to the position and angle of the other object. Handy when moving between axis systems.

New! Change Insertion Point
You can change the position and angle of an inserting object by pre-selecting an existing object before Insert! The inserted object will inherit the position of the selected object. Handy when working with non-default axis.

Insert Line: - use this feature to add reference lines
red green blue - Start position
red green blue - End position
insert!

Insert Horizontal Plane: - use this feature to add reference planes
insert! red (size) green (size) blue (vertical position)

Insert Vertical Plane: - use this feature to add reference planes
insert! red (horizontal position) green (size) blue (vertical size)
insert! red (size) green (horizontal position) blue (vertical size)